Complete a Manual D duct design in another tool using an Amply Manual J load calculation

Instructions for completing a Manual D using third-party tools

Written by Eric Fitz

Amply doesn't currently offer a certified Manual D duct design capability. However, we recommend that our users who need that capability use a platform like Wrightsoft or Kwik Model 3D.

Wrightsoft

In Wrightsoft, there is a Manually override room loads option, which allows you to directly enter in the loads that have already been calculated by Amply.

There is no need to redo the load calculation to complete a Manual D.

  1. Draw simplistic box representations of the rooms in the building (or import a Amply floor plan to sketch on top of it). The rooms do not need to be dimensionally perfect (+/- 2 feet is fine) or detail things like doors or windows. The rooms are simply a place to hold the calculations that have been already completed.

  2. Got to Options -> Manually override room loads and just directly enter the load calculations from Amply. Sensible heating and sensible cooling loads from your room loads are all that are needed (latent is not used for duct design).

  3. Continue with the typical Wrightsoft process for completing a duct design.

Quick video walk through

Courtesy of our friend, Alex Meaney, of Mean HVAC Consulting and Design:

Kwik Model 3D

You can export a screenshot of an Amply floor plan and import that into Kwik Model to complete your duct design design using a similar process.